38 MDS 4710/9710 I/O Guide MDS 05-3305A01, Rev. D
Software upgrades are distributed as ASCII files with a “.S28” exten-
sion. These files use the Motorola S-record format. When the download
is activated, the radio’s
PWR LED flashes rapidly to confirm that a
download is in process. The download takes about two minutes.
NOTE: If a download fails, the radio is left unprogrammed and inop-
erative. This is indicated by the PWR LED flashing slowly (1
second on/1 second off). This condition is only likely if there
is a power failure to the computer or radio during the down-
loading process. The download can be attempted again when
the fault is corrected.
6.6 External Orderwire Module
During installation or troubleshooting activities, it is desirable to com-
municate by voice between personnel at the Master Station and the
Remote Station sites to coordinate their activities. An optional external
orderwire module from GE MDS (P/N 12-1297A01) is available that
can be inserted between the radio’s DATA INTERFACE and the user’s
data communication device.
Invisible place holder
Figure 15. Orderwire Adapter Module
(MDS P/N 12-1307A01)
Installation
Install the Orderwire (O/W) Module between the radio transceiver’s
DATA INTERFACE connector and the connected device. A handset
should also be connected to the associated Master Station’s orderwire
jack.
The payload data exchanges pass through the Orderwire Module unin-
terrupted until the Orderwire Module is in use. The module has a
voice-operated switch (VOX) that keys the connected transceiver when-
ever audio is picked up by a handset plugged into the RJ-11 phone jack.
Any standard telephone handset can be used or a rugged handset (P/N
HANDSET JACK
RED = ORDERWIRE ACTIVE/ TX KEYED
TO RADIO TRANSCEIVER
TO RADIO DATA DEVICE